Ambient pressure, temperature, and relative humidity at a location are $\text{101 kPa}$, $\text{300 K}$, and $60\%$, respectively. The saturation pressure of the water at $\text{300 K}$ is $\text{3.6 kPa}$. The specific humidity of ambient air is ____________________ $\text{g/kg}$ of dry air.

  1. $21.4$
  2. $35.1$
  3. $21.9$
  4. $13.6$

Please log in or register to answer this question.

Related questions

0 0 votes
0 0 answers
557
557 views
go_editor asked Mar 1, 2021
557 views
Consider adiabatic flow of air through a duct. At a given point in the duct, velocity of air is $\text{300 m/s}$, temperature is $\text{330 K}$ and pressure is $\text{180...
0 0 votes
0 0 answers
410
410 views
go_editor asked Mar 1, 2021
410 views
A rigid tank of volume $50 \text{ m}^{3}$ contains a pure substance as a saturated liquid vapour mixture at $\text{400 kPa}$. Of the total mass of the mixture, $20\%$ mas...
0 0 votes
0 0 answers
251
251 views
go_editor asked Mar 1, 2021
251 views
Consider the open feed water heater $\text{(FWH)}$ shown in the figure given below:Specific enthalpy of steam at location $2$ is $\text{2624 kJ/kg}$, specific enthalpy of...
0 0 votes
0 0 answers
499
499 views
go_editor asked Mar 1, 2021
499 views
An adiabatic vortex tube, shown in the figure given below is supplied with $\text{5 kg/s}$ of air (inlet $1$) at $\text{500 kPa}$ and $\text{300 K}$. Two separate streams...

Related questions

0 0 votes
0 0 answers
557
557 views
go_editor asked Mar 1, 2021
557 views
Consider adiabatic flow of air through a duct. At a given point in the duct, velocity of air is $\text{300 m/s}$, temperature is $\text{330 K}$ and pressure is $\text{180...
0 0 votes
0 0 answers
410
410 views
go_editor asked Mar 1, 2021
410 views
A rigid tank of volume $50 \text{ m}^{3}$ contains a pure substance as a saturated liquid vapour mixture at $\text{400 kPa}$. Of the total mass of the mixture, $20\%$ mas...
0 0 votes
0 0 answers
251
251 views
go_editor asked Mar 1, 2021
251 views
Consider the open feed water heater $\text{(FWH)}$ shown in the figure given below:Specific enthalpy of steam at location $2$ is $\text{2624 kJ/kg}$, specific enthalpy of...
0 0 votes
0 0 answers
499
499 views
go_editor asked Mar 1, 2021
499 views
An adiabatic vortex tube, shown in the figure given below is supplied with $\text{5 kg/s}$ of air (inlet $1$) at $\text{500 kPa}$ and $\text{300 K}$. Two separate streams...
Position:
Show:
Answer:

Add Synced Question

×